Bovine AI: the ten-step field procedure

The standard field procedure for loading and using a reusable AI gun with a universal sheath and a frozen straw. Written for trained technicians as a refresher, not as a substitute for certified training.

Current as of 2026-09-01

Procedure

  1. 1

    Inspect and clean the gun

    Wipe the barrel and plunger with a clean dry cloth or disinfectant wipe. Never reuse a gun on a new animal without cleaning.

  2. 2

    Thaw the straw

    Remove with forceps and thaw in a water bath at 35–37 °C for 30–45 seconds. Avoid direct hand contact.

  3. 3

    Dry and inspect

    Wipe dry with a clean paper towel. Check for air bubbles or damage and discard any compromised straw.

  4. 4

    Cut the straw

    Cut the crimped end squarely with a straw cutter. An angled cut leaks.

  5. 5

    Load the gun

    Draw back the plunger, insert the straw cut-end first and seat it fully.

  6. 6

    Fit the sheath

    Slide the universal sheath over the gun. Turn the collar on a twist-lock, or close the clip on a clip-lock.

  7. 7

    Protect and transport

    Cover with a clean sanitary sleeve and keep the gun warm on the way to the animal.

  8. 8

    Restrain and locate the cervix

    Restrain the animal, then insert a lubricated gloved arm rectally to locate and stabilise the cervix.

  9. 9

    Pass through the cervix

    Remove the outer sleeve, wipe the vulva, and guide the gun through the cervical rings into the uterine body.

  10. 10

    Deposit, withdraw and record

    Depress the plunger slowly over 3–5 seconds. Withdraw, discard the sheath and straw, and record bull ID, date and technician.

This is a general field guide, not veterinary instruction. Follow the training and protocols of your certifying body or employer.

Related products

  • Universal AI Sheath, Green BandEx-stock Dhaka

    TDA-SHT-U50G

    Universal AI Sheath, Green Band

    Single-use sterile sheath that houses the semen straw during bovine insemination, protecting it from contamination through the vagina and cervix and delivering the dose into the uterine body. Universal fit takes both 0.25 ml and 0.5 ml straws, so one sheath covers every straw on the tank.

  • Bovine AI Gun, Twist-LockEx-stock Dhaka

    TDA-GUN-TL

    Bovine AI Gun, Twist-Lock

    Reusable stainless steel insemination applicator with a twist-lock collar. The technician loads a thawed straw, seats a universal sheath and turns the collar to lock it — a fixation that holds through cervical passage and releases cleanly afterwards.

  • AI Glove, 90 cm, SensitiveEx-stock Dhaka

    TDA-GLV-090

    AI Glove, 90 cm, Sensitive

    Shoulder-length disposable polyethylene glove for artificial insemination, rectal palpation, pregnancy checking and calving assistance. The sensitive grade is thinned for tactile feedback through the glove without sacrificing tear resistance — the difference between finding the cervix quickly and working blind.